Willow and Hearth

  • Grow
  • Home
  • Style
  • Feast
CONTACT US
Close-up of a blue gas flame burning, like a furnace burner lighting
DIY & Repair

Furnaces That Need A Second Try To Light Are Warning You Before January, And A 15 Minute Walk Through On The First Of The Month Can Catch It

You walk past your furnace all the time. You hear it running and keep going, because it is working, and nobody stops to look at a thing that is working.

Close-up of a blue gas flame burning, like a furnace burner lighting

Ray Dutton spent 25 years on the repair calls that follow, and he says the repair business is counting on that. A lot of the furnaces that quit in January, he says, have been warning people since December, while the house was still warm.

In his video on Ray Dutton’s Garage, he lays out a simple monthly routine: one 15 minute walk through the house on the first of every month, with no tools and nothing on the furnace taken apart.

A Furnace That Needs A Second Try To Light Is Already Talking

The easiest sign takes only a phone. A healthy furnace lights on the first try, and on most furnaces it goes from the thermostat to the big fan in under two minutes, with many landing between one minute and a minute and a half.

A furnace that needs a second try, or suddenly takes much longer than last month, is telling you something. Dutton says a furnace that cannot prove it has a flame shuts the gas off and starts over, and most get three or four tries before they lock themselves out for an hour, sometimes three. “That’s your Saturday morning,” he says.

It Is 11 Degrees Out, The Thermostat Says 61, And Only One Company Answers

Dutton paints the January scene. The cold wakes you on a Saturday, the furnace tries, quits and tries again, and a light blinks at you. The one company that answers can come tonight, at the weekend rate.

The average furnace repair, he says, runs a little over $300, and a weekend add on is often another $150 to $300. That puts you at $500 or $600 for a job that might have been $300 on a Tuesday in December.

He also says American homes burn about four times as much gas in January as in October, so the one trained look a furnace gets all year comes before its hardest work.

Minute One Through Four, Where A $6 Filter Beats A $560 Motor

Start at the thermostat and just read it. Is the screen lit, does it say heat, and is it set where you think? If you see a low battery warning, change the batteries that day, because a dead thermostat cannot start the furnace and a visit to swap a few dollars of batteries starts at $100 or more.

Next comes the filter, checked before the furnace starts. Put it next to a new one, and if it is gray with packed folds, replace it and write the date on the frame. A packed filter starves the furnace of air, the inside overheats and a safety cuts the fire while the fan keeps blowing cool air.

A filter costs about $6, Dutton says, while a new blower motor averages about $560 and can reach $2,400. Then look at the floor. A couch moved for the tree, a rug over a register or boxes against the big return grille all choke the airflow, and clearing them is free.

Set The Stopwatch And Listen For The Squeal, The Hum And The Boom

Wait until the furnace is off, set the thermostat two degrees over the room, start a stopwatch as you press the button and walk to the furnace. First comes a small fan winding up for 15 to 30 seconds, then the igniter glows for 15 to 20 seconds, then the burners catch with a soft whoosh. About 30 to 45 seconds later the big fan starts.

A high squeal from that small fan can mean worn bearings, a repair he says runs $400 to $1,100 installed. A hum before the big fan spins usually means a weak capacitor, which is a daytime call. A boom when the burners light means you should turn it off at the thermostat and call that day, because that is gas lighting late.

The flame should be steady and blue. A lazy yellow flame on a gas furnace means shut it off and call. If you smell gas anywhere on the walk, touch no switches, get everybody out and call your gas company or 911 from outside.

Water, Pipes And Heat Pumps Have Their Own Warning Signs

A furnace that vents through plastic pipe can make five gallons or more of water a day in cold weather, so the floor around it should be dry. When that water cannot get out, a safety shuts the fire off on purpose, and a call runs $100 to $400, often with nothing broken.

Outside, keep about three feet clear of snow around plastic vent pipes on the side wall and look for a ring of ice at the tip. Never hit a cold plastic pipe, because it can crack.

On a heat pump, keep two feet clear around the outdoor unit. Thin frost is normal, Dutton says, but thick ice that is still there an hour later is not, and the compressor inside runs $1,500 to $3,500.

Minute 14 Is The Stop With No Price On It

Press the test button on your carbon monoxide alarm. The federal safety agency says to do that every month, and Dutton adds that the beep proves the horn works but not the sensor, so read the replacement date on the back too.

He says the federal safety agency counted about 200 carbon monoxide deaths a year from consumer products like heaters and generators, from 2012 through 2022, with January the worst month at about one death a day. A cracked heat exchanger can cost $1,250 to $3,000, but you cannot see that crack from the hallway.

Write It On Masking Tape And Call In The Daytime

Last, tear off a strip of masking tape, stick it on the side of the cabinet and write the date, your seconds, how many tries and what the status light did. It might read 95 seconds, one try, light steady. Each month’s strip goes right under the last, and by March the cabinet holds the whole winter.

If something looks off, run the count again the next week. A second try to light, a squeal, a gurgle that will not quit or a number that has moved two months in a row means you call that week, in the daytime. Done right, you have moved the repair from a Saturday night in January to a Tuesday morning in December.

Dutton is straightforward about the limits. A control board can die with no warning, and he says one big consumer survey has about one gas furnace in four breaking down by year 10. This walk is also no stand in for the yearly service, since the same federal agency says to have the system inspected and serviced every year.

When you do call, he suggests this sentence: “It’s needing a second try to light, and that started after your last visit. Before you replace anything, can you read me the fault history off the board, and tell me what the flame signal reads against what the maker wants? Please put both on the invoice.”

More Stories You May Like

  • Neighbor Keeps Taking Her Trash Can Off The Porch And Bringing It Back, Then Ring Cameras Catch Her Standing Out Front Holding Up A Phone And Whispering It’s Gone
  • Illinois Landlords Will Have To List Every Mandatory Fee On The First Page Of The Lease Starting In 2027, And Any Fee Left Off Is One The Tenant Does Not Have To Pay
  • Homeowner Hosts 141 Guests During 36 Short Term Stays Despite Neighborhood Rules, Then The State Supreme Court Votes 5 To 4 That Renting It Out Is A Business And Upholds $8,528 In Fines
←Previous

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Search

Categories

  • DIY & Repair
  • Feast & Festivity
  • Gather & Grow
  • Home & Harmony
  • Home Improvement & Renovation
  • Home Maintenance & Seasonal Prep
  • Home Safety & Recalls
  • Money-Saving Home Hacks
  • Style & Sanctuary
  • Tools & Gear
  • Trending
  • Uncategorized

Archives

  • November 2026
  • October 2026
  • September 2026
  • August 2026
  • July 2026
  • June 2026
  • May 2026
  • April 2026
  • March 2026
  • February 2026
  • January 2026
  • December 2025
  • November 2025
  • October 2025
  • July 2025
  • June 2025
  • March 2025

Latest Post

  • Furnaces That Need A Second Try To Light Are Warning You Before January, And A 15 Minute Walk Through On The First Of The Month Can Catch It
  • New York Couple Moves Into A Brand New Apartment, Then A Mystery Tapping Behind The Bathroom Wall Gets So Loud Engineers Bust Open The Shower And Find A Pipe Expanding
  • Plumber Shows A Double Wall Copper Drain In A Custom Utah Home That Steals Heat From Shower Water To Preheat The Cold Line Going To The Water Heater

Willow and Hearth

Willow and Hearth is your trusted companion for creating a beautiful, welcoming home and garden. From inspired seasonal décor and elegant DIY projects to timeless gardening tips and comforting home recipes, our content blends style, practicality, and warmth. Whether you’re curating a cozy living space or nurturing a blooming backyard, we’re here to help you make every corner feel like home.

Contact us at:
[email protected]

    • About
    • Blog
    • Contact Us
    • Editorial Policy
    • Privacy Policy
    • Terms and Conditions

© 2025 Willow and Hearth